Product Specification
BENCH TOP OXYGEN ANALYSER, Measurement Range: Instrument with micro fuel sensors or electrochemical sensors to determine oxygen concentration in ppm between 0 to 2000ppm, Sensitivity: 0.5% of full scale, Accuracy: +-2% of scale or +-1 ppm at constant temperature; (Whichever is greater) +-5% of reading or +-1 PPM over the operating temperature range. (Whichever is greater), Repeatibility: +-0.1% of Full Scale at Constant Temperature, Response Time: <60 seconds or less percent ranges, Operating Temperature: 0 to 40 Degree Celsius or above, Humidity <90%, Display: Graphic LCD/LED display with backlight, Alarm Warning: Integrated Buzzer and Vibrato, System Power: With 10-14 hour runtime rechargeable inbuilt batteries along with AC adaptor for battery charging, Zero Calibration: Automatic at Instrument start up with ambient fresh air sample, Sensor Type: Long-Life, maintenance free with CO2 Resistant and Easily Replaceable, Special Feature: Intrinsically Safe, FM/FMc or ATEX or TUV approved, Gas Connections: Stainless Steel Compression Fittings, Accessories: Durable Plastic, Foam Interior or larger case for a unit with a sample system. Rota Meter, Replacement Kit, Inline Fitters, Moisture Trap Filters, Needle Valve, 10 Meter Tube and fitting for tubing suitable for instrument and USB Cable. All accessories should be from OEM. If any Other item is Required to run the system that should be included, Guaranty/ Warranty: One year from the date of acceptance of material, Additional Information: Instrument should be supplied with OEM Calibration Certificate along with Traceability Certificate (NPL), Installation/ Demonstration should be required, Gas Composition: Bench Top Oxygen Analyzer to analyze the oxygen concentration in ppm in Process Gas and exhaust gas having other gas composition- Ar: 0-5.0%, N2: 0-99.0%, CO: 0-99.0%, CO2: 0-99.0%, CH4: 0-99.0%, H2: 0-99.0% using Sensor Technology for incredibly fast and reliable results, Make and Model Number need to specify.
Application
The ambient temperature electrochemical sensor is also referred to as a galvanic sensor, which is a small, partially sealed, cylindrical device that contains two dissimilar electrodes immersed in an electrolyte. The oxygen molecules diffuse in the electrolyte, and that results in a chemical reaction which generates a certain amount of current that tells us the level of oxygen in the system. Similarly, a paramagnetic analyzer works on a simple principle, that oxygen has a very high magnetic susceptibility, and shows a paramagnetic behavior. Polarographic analyzers work well in case of percent measurement, and the main advantage is that when it is not in operation, there is no consumption of electrodes. It can be stored for a longer duration of time